| Customization: | Available |
|---|---|
| Type: | Insulated |
| Conductor Type: | Stranded |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency




House Cable Parameter Category | House Cable Key Specification | House Cable Details/Options | House Cable Testing Standar |
Core Parameters | Rated Voltage | 220V, 110V, 200V, 450V, 300V, 230V | IEC 60245, GB/T 5013 |
Conductor Material | Bare copper, tinned copper (Class 2/5/6 flexibility) | IEC 60228 | |
Insulation Material | EPR (Ethylene Propylene Rubber) or XLPE | IEC 60502-1 | |
Jacket Material | PVC , CPE, or halogen-free compound | IEC 60754, IEC 61034 | |
Electrical Performance | Max. Operating Temp. | 70°C (standard), 90°C (high-temp variant) | IEC 60245-4 |
Min. Operating Temp. | -20°C (standard), -40°C (arctic grade) | IEC 60811-504 | |
Voltage Test | Low Voltage | IEC 60060 | |
Mechanical Properties | Bending Radius | 4× cable diameter (fixed installation) | IEC 61386 |
Tensile Strength | ≥10 N/mm² (jacket) | IEC 60811-1-1 | |
Flame Retardancy | IEC 60332-1 (single), IEC 60332-3 (bundle) | IEC 61034 (low smoke) | |
Certifications | International Standards | CE, RoHS, REACH, UKCA | (Attach report links) |
Industry Certificates | UL/CSA (optional), TUV, SGS | 2(Verified suppliers) | |
Customization Available | Conductor Size | 0.5mm² to 35mm² | (Specify tolerances) |
Color Coding | Custom PVC jacket colors | ISO 17853 |
















