House Cable Parameter Category | House Cable Key Specification | House Cable Details/Options | House Cable Testing Standar |
Core Parameters | Rated Voltage | 220V, 300/500V, 450/750V, 0.6/1kV | IEC 60245, GB/T 5013 |
Conductor Material | Bare copper, tinned copper (Class 2/5/6 flexibility) | IEC 60228 | |
Insulation Material | EPR (Ethylene Propylene Rubber) or XLPE | IEC 60502-1 | |
Jacket Material | PVC (Type ST1/ST2), CPE, or halogen-free compound | IEC 60754, IEC 61034 | |
Electrical Performance | Max. Operating Temp. | 70°C (standard), 90°C (high-temp variant) | IEC 60245-4 |
Min. Operating Temp. | -20°C (standard), -40°C (arctic grade) | IEC 60811-504 | |
Voltage Test | 2.5kV AC, 50Hz, 5 mins (pass) | IEC 60060 | |
Mechanical Properties | Bending Radius | 4× cable diameter (fixed installation) | IEC 61386 |
Tensile Strength | ≥10 N/mm² (jacket) | IEC 60811-1-1 | |
Flame Retardancy | IEC 60332-1 (single), IEC 60332-3 (bundle) | IEC 61034 (low smoke) | |
Certifications | International Standards | CE, RoHS, REACH, UKCA | (Attach report links) |
Industry Certificates | UL/CSA (optional), TUV, SGS | 2(Verified suppliers) | |
Customization Available | Conductor Size | 0.5mm² to 35mm² | (Specify tolerances) |
Color Coding | Custom PVC jacket colors (RAL/BS codes) | ISO 17853 |